跳转到主要内容
首页

Dedicated to discovery

  • 关于 ELGA
    • 关于 ELGA
    • 招贤纳士
    • 活动
  • 支持
    • 实验室规划
  • 联系信息
  • EN
  • DE
  • ES
  • FR
  • IT
  • PT
  • JA
  • EN-US
首页
  • 产品
    • PURELAB
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 7/15
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA® BIOX
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY 30
    • ELGA 全产品系列
  • 应用
    • 一般实验室用水要求
    • 临床生物化学
    • 免疫化学
    • 分光光度测定法:
    • 原子光谱分析法
    • 微生物分析
    • 气相色谱分析法
    • 液相色谱
      • High Performance Liquid Chromatography
    • 电化学
    • 细胞培养
    • 质谱分析法
    • 遗传学
    • 高效液相色谱 (HPLC)
  • 水纯化技术
    • PureSure
    • 反渗透法
    • 活性碳
    • 电去离子法
    • 离子交换法
    • 紫外线照射法
    • 过滤
  • 水中杂质
    • 微生物和细菌
    • 微粒
    • 无机化合物
    • 有机化合物
    • 溶解气体
  • 知识
    • BROSCHÜREN
    • 博客
    • 案例分析
    • 超纯水
    • 白皮书
  • 如何购买?
  • 联系信息
Home
  • 联系信息
  • 产品
    • PURELAB
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 7/15
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA® BIOX
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY 30
    • ELGA 全产品系列
  • 应用
    • 一般实验室用水要求
    • 临床生物化学
    • 免疫化学
    • 分光光度测定法:
    • 原子光谱分析法
    • 微生物分析
    • 气相色谱分析法
    • 液相色谱
      • High Performance Liquid Chromatography
    • 电化学
    • 细胞培养
    • 质谱分析法
    • 遗传学
    • 高效液相色谱 (HPLC)
  • 水纯化技术
    • PureSure
    • 反渗透法
    • 活性碳
    • 电去离子法
    • 离子交换法
    • 紫外线照射法
    • 过滤
  • 水中杂质
    • 微生物和细菌
    • 微粒
    • 无机化合物
    • 有机化合物
    • 溶解气体
  • 知识
    • BROSCHÜREN
    • 博客
    • 案例分析
    • 超纯水
    • 白皮书
  • 如何购买?
  • 联系信息
  • 关于 ELGA
    • 关于 ELGA
    • 招贤纳士
    • 活动
  • 支持
    • 实验室规划
  • 联系信息
  • EN
  • DE
  • ES
  • FR
  • IT
  • PT
  • JA
  • EN-US
  • 隐私政策
  • 条款和条件
  • 全球法律合规
  • 专利
  • Trademarks
  • 页面操作员
  • What is CLSI Water?
Water In The Lab
Water Purity

What is CLSI Water?

24 7月 2023
- by Dr Paul Whitehead

Scientist holding a sphere displaying digital icons relating to science and medicine

CLSI Water is Clinical Laboratory Reagent Water (CLRW) as defined in Clinical and Laboratory Standards Institute document “Preparation and Testing of Reagent Water in the Clinical Laboratory; Approved Guideline-Fourth Edition”. This is still a key reference document for water purity in clinical laboratories. Collegiate of American Pathologists (CAP) accreditation is used in laboratories around the world. The CAP recommendation is that, as a minimum, water in the laboratory should meet Clinical Laboratory Reagent Water (CLRW) as specified by CLSI.

Clinical Laboratory Reagent Water (CLRW) specification is:

Bacteria     <10 CFU/ml
Resistivity  >10 MΩ.cm
TOC             <500 PPB
Particles     0.2um filtration or better


The CLSI guideline also states that for instrument feed water – “Use of CLRW for this application must be confirmed with the manufacturer of a specific instrument. Water meeting the manufacturer’s specifications must be used.” CLSI clearly anticipate that CLRW may not be pure enough for all analyzer feeds. The onus is on the analyzer company to validate their chemistries and use purified water of a suitable purity to give accurate and reproducible results. 

CLRW Specification Limits 4 Types of Impurity in Laboratory Water

The CLRW specification limits four key types of impurity in pure water:

  • Ions
  • Particulates
  • Organics
  • Bacteria and bacterial by-products


All will impact on clinical analyzer performance, either by direct interference with the chemistries of tests or indirectly, by introducing errors in the measurements.

Ionic Impurities and CLSI Water

The CLRW resistivity specification of >10MΩ.cm restricts the concentrations of ionic impurities to ppb levels or less and, in effect, requires the elimination of carbon dioxide. This is adequate for most clinical work including general chemical, electrolyte, lipid and protein assays, enzymology, enzyme immunoassay, toxicology and therapeutic drug monitoring and, more recent, molecular biological techniques. When trace elements need to be determined, the water resistivity needs to be much higher – at 18.2 MΩ.cm.

Low Levels of Particulates in CLSI Water

The absence of particulates is a general requirement for all types of application and is especially critical with the low liquid volumes used in modern assays. Particles can clog needles and sample handling manifolds. Deposits of particles encourage the formation of bio-film and bacterial growth and can affect the transmissivity and path length of spectroscopic cells. CLRW relies on filtration to remove particulates. However, the 0.2 µm filters specified may not always be adequate.

Total Organic Carbon (TOC)

Similarly, the TOC spec of <500 ppb in CLRW is a reflection of earlier standards and allows scope for the presence of a wide variety of organic compounds such as carboxylic acids and polyaromatics, which could jeopardize assays. Carboxylic acids can interfere with enzymology and enzyme immunoassays by binding to active sites and complexing with co-factor metals. Other organics can inhibit enzymes and affect fluorescent detection.  

Reducing Bacterial Contamination in CLRW

Bacterial contamination has serious effects on all aspects of analyzer operation. The key is achieving consistently low levels. For example, problems can arise in immunoassay due to flurescein-based dye released from bacteria (e.g. Pseudomonas Aureuginosa) giving high blanks and out-of-range standards during calibration and false positives with samples.  
             
Specifications or recommendations are also provided for five other types of purified water to meet different needs in clinical laboratory testing but CLRW is the only one specified in detail. Throughout the document, CLSI emphasizes the need for good practice and rigorous trending of water system parameters for all types of water to ensure that water purity is achieved and maintained. Ultrapure Water must be validated as fit for purpose and water purification system validation is strongly recommended.

Dr Paul Whitehead 

After a BA in Chemistry at Oxford University, Paul focused his career on industrial applications of chemistry. He was awarded a PhD at Imperial College, London for developing a microwave-induced-plasma detector for gas chromatography. He spent the first half of his career managing the analytical support team at the Johnson Matthey Research/Technology Centre,specialising in the determination of precious metals and characterising applications such as car-exhaust catalysts and fuel cells. Subsequently, as Laboratory Manager in R&D for ELGA LabWater, he has been involved in introducing and developing the latest water purification technologies. He now acts as a consultant for ELGA.

 

To discuss your clinical laboratory water requirements, please contact ELGA or an Approved Partner in your country.

  • 留言咨询
  • 获取报价
  • 预订演示
  • 联系获认证的合作伙伴

留言咨询

在 ELGA LABWATER,我们希望能够为您提供有关我们实验室水纯化产品的精彩优惠和新闻动态。 我们将使用您提供的信息来预测您可能会感兴趣的内容。 我们会慎重处理您的数据,您可在此查阅我们的隐私政策。

ELGA LABWATER 的所有合作伙伴均已通过我们的审慎审核和认证。 为了对您的问题或查询进行回复,我们可能将您的联系详情转发给获认证的合作伙伴,由他们直接与您联系。 您可在此查看我们的获认证业务合作伙伴名单。

如果您希望接收来自 ELGA 及我们获认证合作伙伴的最新动态,请勾选下框: 在此.

是,我希望 ELGA LabWater 及其获认证合作伙伴基于我的联系详情为我发送其最新动态

获取报价

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

I'd like to receive updates from ELGA LabWater & ELGA Approved Partners based on my details.

预订演示

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

I'd like to receive updates from ELGA LabWater & ELGA Approved Partners based on my details.

Call us

Can't find what you are looking for?

Support Number
+44 (0)20 3567 7300
United Kingdom Sales
+44 (0)1628 879 704
United States of America Sales
+1 877-315-3542
France Sales
+33 1 40 83 65 00
China Sales
+86 400-616-8882

 

Elga LabWater 总部

ELGA Labwater英国总部

VWS(UK)Ltd.

Lane End Business Park,Lane End,High Wycombe

HP14 3BY,United Kingdom

ELGA Labwater中国总部

威立雅水处理技术(上海)有限公司

地址 : 上海市浦东新区张东路1761号5号楼
电话 : 021 - 38172288
传真 : 021 - 38172289
邮编 : 201210

案例研究

  • 雅培诊断
  • DASA 医学诊断
  • NeoDIN 医学研究所
  • 北斯塔福德郡 NHS 信托大学医院
  • Olsberg 职业技术学院

学习资源

  • 了解超纯水
  • 白皮书
  • 水纯化技术
  • 实验室应用
  • 水中杂质
  • Latest Blog
  • Water Purity - Different Types of Pure Water
  • What is Clinical Laboratory Reagent Water (CLSI)?
  • What is Total Organic Carbon (TOC)?

© VWS (UK) Ltd. 以 ELGA®LabWater 的名义经营业务。2025- 保留所有权利
ELGA 是 Veolia 旗下全球实验室用水品牌。

备案号:沪ICP备20001142号-1

  • 隐私政策
  • 条款和条件
  • 全球法律合规
  • 专利
  • Trademarks
  • 页面操作员
  • 语言
    • Deutsch
    • English
    • Español
    • Français
    • Italiano
    • Português
    • 日本語
    • 中文
  • Veolia 其他站点
    • Veolia
    • Veolia Foundation
    • Veolia Water Technologies
Elga Veolia
TOP

© 2017 ELGA Veolia