跳转到主要内容
首页

Dedicated to discovery

  • 关于 ELGA
    • 关于 ELGA
    • 招贤纳士
    • 活动
  • 支持
    • 实验室规划
  • 联系信息
  • EN
  • DE
  • ES
  • FR
  • IT
  • PT
  • JA
  • EN-US
首页
  • 产品
    • PURELAB
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 7/15
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA® BIOX
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY 30
    • ELGA 全产品系列
  • 应用
    • 一般实验室用水要求
    • 临床生物化学
    • 免疫化学
    • 分光光度测定法:
    • 原子光谱分析法
    • 微生物分析
    • 气相色谱分析法
    • 液相色谱
      • High Performance Liquid Chromatography
    • 电化学
    • 细胞培养
    • 质谱分析法
    • 遗传学
    • 高效液相色谱 (HPLC)
  • 水纯化技术
    • PureSure
    • 反渗透法
    • 活性碳
    • 电去离子法
    • 离子交换法
    • 紫外线照射法
    • 过滤
  • 水中杂质
    • 微生物和细菌
    • 微粒
    • 无机化合物
    • 有机化合物
    • 溶解气体
  • 知识
    • BROSCHÜREN
    • 博客
    • 案例分析
    • 超纯水
    • 白皮书
  • 如何购买?
  • 联系信息
Home
  • 联系信息
  • 产品
    • PURELAB
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 7/15
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA® BIOX
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY 30
    • ELGA 全产品系列
  • 应用
    • 一般实验室用水要求
    • 临床生物化学
    • 免疫化学
    • 分光光度测定法:
    • 原子光谱分析法
    • 微生物分析
    • 气相色谱分析法
    • 液相色谱
      • High Performance Liquid Chromatography
    • 电化学
    • 细胞培养
    • 质谱分析法
    • 遗传学
    • 高效液相色谱 (HPLC)
  • 水纯化技术
    • PureSure
    • 反渗透法
    • 活性碳
    • 电去离子法
    • 离子交换法
    • 紫外线照射法
    • 过滤
  • 水中杂质
    • 微生物和细菌
    • 微粒
    • 无机化合物
    • 有机化合物
    • 溶解气体
  • 知识
    • BROSCHÜREN
    • 博客
    • 案例分析
    • 超纯水
    • 白皮书
  • 如何购买?
  • 联系信息
  • 关于 ELGA
    • 关于 ELGA
    • 招贤纳士
    • 活动
  • 支持
    • 实验室规划
  • 联系信息
  • EN
  • DE
  • ES
  • FR
  • IT
  • PT
  • JA
  • EN-US
  • 隐私政策
  • 条款和条件
  • 全球法律合规
  • 专利
  • Trademarks
  • 页面操作员
  • Dissolved Gases in Purified Water
Water Purity
Water In The Lab

Dissolved Gases in Purified Water

12 5月 2023
- by Dr Paul Whitehead

Degassing Water Dissolved Gas

There are dissolved gases in most purified water. What are they? How much is there? How do they get there? What effects do they have?

All purified water is produced by removing impurities from natural or municipal waters. We need, therefore, to consider the gases possibly present in these feed-waters, their fates as the waters is purified and any potential contamination with the same or other gases during or after purification.
 

Dissolved Gases in Natural Waters

Natural waters are, to a greater or lesser extent, in contact with air. Most of the dissolved gases are absorbed from the air plus CO2 which can come in part from soil and rocks in contact with the water. Municipal waters are obtained by treating natural waters to make them safe to drink. These processes tend to have very little effect on the dissolved gas content of the water, generally increasing their contact with ambient air and reducing the variability due to local sources.

Every atmospheric gas is in equilibrium with that gas dissolved in water. The amount dissolved in water depends on the temperature and the partial pressure of the gas in the atmosphere.

Gas Content of Natural Water

The molar concentration of a gas, i, dissolved in water in contact with air is given by:

[gasi(aq)] = Pi/KH where Pi is its volume proportion in air and KH is its equilibrium constant

 

Gas

Volume

KH

Concentration in Water at 25°C

Name

 %

atm/Mole

mg/L

Nitrogen

78.08

1639.3

13.34

Oxygen

20.95

769.2

8.72

Argon

0.93

714.3

0.052

Neon

0.0018

2222.2

0.000016

Helium

0.0005

2702.7

0.0000004

Typical percentages of gases in air, their equilibrium constants with water and the resulting concentrations in water in contact with air.

 

 

The concentrations of dissolved gases in water will vary with temperature, atmospheric pressure, and location but for water at equilibrium with air at 25°C the approximate gas content of natural waters are listed in column 4. In summary, in feed-water to purification systems, there are concentrations of oxygen and nitrogen at <10ppm levels and only traces of noble gases. The level of CO2 in the water is influenced by other factors and is discussed separately.
 

Effect of Water Purification on Dissolved Gases

The effects of standard water purification technologies on dissolved oxygen, nitrogen and the inert gases are negligible. These gases will pass straight through reverse osmosis membranes, UV light, micro and ultra-filters, ion exchange resins and electrodeionisation (EDI) units and do not use any of the capacity of the purification media. Any minor effects due, for example, to local changes of pressure will tend to be balanced out by equilibration with the atmosphere in any storage vessel. Feed water from municipal supplies is likely to warm as it purified in the laboratory and, as a result, the purified water is more likely to be saturated in nitrogen and oxygen.
 

Carbon Dioxide

Carbon dioxide behaves very differently from the other gases in air. When it dissolves in water, it reacts to set up a series of equilibria:

Equation for Dissolved CO2 in Water

CO2 + H2O  ↔  H2CO3  ↔  H+ + HCO3-  ↔  2H+ + CO32-

A small fraction of the carbon dioxide dissolved in water reacts rapidly to form carbonic acid. This, in turn, partially dissociates to form hydrogen, bicarbonate and carbonate ions. CO2 will continue to dissolve until equilibrium is reached.

The situation is further complicated by the presence of carbonate and bicarbonate ions in hard natural waters. These concentrations can be relatively high, resulting in high levels of carbonic acid and dissolved CO2. In these circumstances, dissolved CO2 concentrations can be 60ppm or more.

Like other gases, CO2 will pass unaltered through filters and UV treatment, however, due to its equilibrium with bicarbonate and carbonate ions, it can, in effect, be retained on anion exchange resins. As the bicarbonate and carbonate ions are removed on the resin, more CO2 will convert to bicarbonate until none remains.

Impact of Water Purification on Dissolved CO2

1)    CO2 is removed completely from water that has been purified by ion-exchange or, to a large extent, by EDI.

2)    High levels of CO2 will use up a significant amount of the capacity of the ion-exchange resin bed or could overload EDI. With 25ppm CO2 in the feed-water over two-thirds of the capacity of the mixed-bed resins can be used up by the CO2.

3)    With high CO2 feed waters removal of the CO2 prior to ion-exchange could increase pack lifetimes by a factor of three or more.
 

After Removing Dissolved Gases

After removing dissolved gases to purify the water, ultrapure water within the purifier has a resistivity of 18.15 MΩ.cm and contains sub-ppb levels of all impurities except dissolved oxygen and nitrogen.

Resistivity of Pure Water in Contact with Air

As soon as this water is dispensed into a vessel in the laboratory it comes into contact with air. The oxygen and nitrogen contents do not change significantly but CO2 will rapidly be absorbed from the air; hydrogen, bicarbonate and carbonate ions will be produced and the resistivity will fall to about 1.3 MΩ.cm as shown in Figure 1. In normal laboratory practice this is unavoidable. The high conductance of the hydrogen ions means that this change only corresponds to a concentration of 0.5 mg/L CO2 in solution. This does not affect most experimentation and, with good laboratory practice, the purity of the water is otherwise unaffected. 

Typical percentages of gases in air, their equilibrium constants with water and the resulting concentrations in water in contact with air.
Figure 1 Degradation of pure water resistivity in contact with air

 


Degassing of Oxygen and Nitrogen and Carbon Dioxide

Degassing to reduce the concentration of dissolved CO2 before ion exchange or EDI is highly desirable to increase resin pack life and ensure the effectiveness of EDI.

What is Degassing?

Degassing refers to the removal of dissolved gases for liquids, usually water or aqueous solutions. Degassing water is best carried out in the permeate from reverse osmosis (RO). At that stage, most of the ions have been removed and the pH of the water is slightly acidic; the equilibrium concentration of C02 is reduced.

For laboratory scale units hydrophobic filters are used. RO permeate flows through a bundle of microporous hollow fibers (usually polypropylene) and air sweep gas at reduced pressure flows past the outside of the fibers. The partial pressure of the CO2 in the air outside the fibers is much lower than in the water and so CO2 is removed from the water into the gas stream. Turbulence within the sweep gas makes the process more efficient but with small units, complete removal of dissolved gases is not possible. However, under suitable conditions, over 80% of CO2 can be removed with an air sweep gas.

Why is degassing important in purified water?

The removal of oxygen/nitrogen from pure water on a laboratory scale is usually done where there is concern that bubbles of gas will be released as the pressure or temperature of the water varies. This can cause blocking of fine tubes or interfere with spectrophotometric measurements due to bubbles in cells.

If the water is being degassed to reduce levels of oxygen and/or nitrogen, the same type of degasser module can be used with a vacuum applied to the outer chamber. It is best carried out on the water in the final purification loop. Oxygen and nitrogen will be reabsorbed if there is any contact with air so any such degassed water must be used via a direct link to the apparatus. For HPLC and IC this is often most conveniently achieved after water purification by sparging a reservoir with helium to remove dissolved gases. 

 

Dr Paul Whitehead 

After a BA in Chemistry at Oxford University, Paul focused his career on industrial applications of chemistry. He was awarded a PhD at Imperial College, London for developing a microwave-induced-plasma detector for gas chromatography. He spent the first half of his career managing the analytical support team at the Johnson Matthey Research/Technology Centre,specialising in the determination of precious metals and characterising applications such as car-exhaust catalysts and fuel cells. Subsequently, as Laboratory Manager in R&D for ELGA LabWater, he has been involved in introducing and developing the latest water purification technologies. He now acts as a consultant for ELGA.

  • 留言咨询
  • 获取报价
  • 预订演示
  • 联系获认证的合作伙伴

留言咨询

在 ELGA LABWATER,我们希望能够为您提供有关我们实验室水纯化产品的精彩优惠和新闻动态。 我们将使用您提供的信息来预测您可能会感兴趣的内容。 我们会慎重处理您的数据,您可在此查阅我们的隐私政策。

ELGA LABWATER 的所有合作伙伴均已通过我们的审慎审核和认证。 为了对您的问题或查询进行回复,我们可能将您的联系详情转发给获认证的合作伙伴,由他们直接与您联系。 您可在此查看我们的获认证业务合作伙伴名单。

如果您希望接收来自 ELGA 及我们获认证合作伙伴的最新动态,请勾选下框: 在此.

是,我希望 ELGA LabWater 及其获认证合作伙伴基于我的联系详情为我发送其最新动态

获取报价

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

I'd like to receive updates from ELGA LabWater & ELGA Approved Partners based on my details.

预订演示

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

I'd like to receive updates from ELGA LabWater & ELGA Approved Partners based on my details.

Call us

Can't find what you are looking for?

Support Number
+44 (0)20 3567 7300
United Kingdom Sales
+44 (0)1628 879 704
United States of America Sales
+1 877-315-3542
France Sales
+33 1 40 83 65 00
China Sales
+86 400-616-8882

 

Elga LabWater 总部

ELGA Labwater英国总部

VWS(UK)Ltd.

Lane End Business Park,Lane End,High Wycombe

HP14 3BY,United Kingdom

ELGA Labwater中国总部

威立雅水处理技术(上海)有限公司

地址 : 上海市浦东新区张东路1761号5号楼
电话 : 021 - 38172288
传真 : 021 - 38172289
邮编 : 201210

案例研究

  • 雅培诊断
  • DASA 医学诊断
  • NeoDIN 医学研究所
  • 北斯塔福德郡 NHS 信托大学医院
  • Olsberg 职业技术学院

学习资源

  • 了解超纯水
  • 白皮书
  • 水纯化技术
  • 实验室应用
  • 水中杂质
  • Latest Blog
  • Water Purity - Different Types of Pure Water
  • What is Clinical Laboratory Reagent Water (CLSI)?
  • What is Total Organic Carbon (TOC)?

© VWS (UK) Ltd. 以 ELGA®LabWater 的名义经营业务。2025- 保留所有权利
ELGA 是 Veolia 旗下全球实验室用水品牌。

备案号:沪ICP备20001142号-1

  • 隐私政策
  • 条款和条件
  • 全球法律合规
  • 专利
  • Trademarks
  • 页面操作员
  • 语言
    • Deutsch
    • English
    • Español
    • Français
    • Italiano
    • Português
    • 日本語
    • 中文
  • Veolia 其他站点
    • Veolia
    • Veolia Foundation
    • Veolia Water Technologies
Elga Veolia
TOP

© 2017 ELGA Veolia